One moment please...

Thermo Scientific Shandon Xylene Substitute is specifically designed to be used for tissue processing and staining of histological and cytological specimens. The product is a clear, colorless reagent blend of isoparaf- finic hydrocarbons that have the same evaporation rate as xylene and is highly quality controlled.

Thermo Shandon Limited is an ISO 9001 and TickIT Accredited Company Thermo Fisher Scientific is the trading name of Thermo Shandon Limited All information contained in this manual is proprietary and confidential, and the exclusive property of Thermo Fisher Scientific. This manual is protected by copyright and reproduction is prohibited. Thermo Shandon imited. Xylene can be used with both open and closed tissue processors. Compatible with manual staining procedures and automatic.

Thermo Shandon Processor Manual
Not A Member?Sign Up
Thermo

Thermo Fisher Scientific - Shandon Pathcentre
by Thermo Fisher Scientific

  • Videos
  • News
DESCRIPTION
Thermo Shandon Processor ManualThermo shandon processor manual 2016

High-volume, totally enclosed tissue processor.

The Shandon Pathcentre is a high-volume, totally enclosed tissue processor that allows complete user control and excellent continuous reagent agitation.

FORUMSView All (9)
Ask a New Question

1

Reply
-RSD
4 years ago
4 years agoError 25

Shandon Pathcentre has given a 'Non continuable error combination.' (Error 25) We are trying to find a way to fix this error ourselves since we have been informed that there is no longer support for our model. Any help would be appreciated!

Reply
-MYRSEBAS
6 years ago
6 years agoMEZCLA DE LIQUIDOS DEL EQUIPO SHANDON PATHCENTER DE PATOLOGIA

por favor queremos saber porque se mezclan los líquidos del equipo por ejemplo xiloles con alcoholes y el alcohol se va a la parafina que problema tiene el equipo gracias

Reply

4

Replies
-esillc
7 years ago
7 years agoNeed copy of operators manual for Thermo Shandon Pathcentre

This is for a Thermo Shandon Pathcentre tissue processor. Need a copy of operators manual Willing to pay for making a copy of manual or electronic copy. I do not have an operators manual and need one. Thanks in advance for your help.

Reply

Thermo Shandon Catalog

DOCUMENTS / MANUALSView All

Thermo Shandon Excelsior Processor Manual

FEATURES

  • Up to 306-cassette capacity plus the ability to add up to three extra processing modules for high throughput laboratories.
  • Fumes stay within the system, and do not escape into your lab
  • Gentle counter-stir agitation and Shandon tidal flow system promotes maximum fluid penetration through baskets and cassettes for the ultimate in processing quality and consistency
  • 4 wax baths provide excellent specimen infiltration
  • Glass reaction chamber lid allows visual inspection of processing
  • Lid automatically locks during processing
  • Flexible Programming
  • Real time programming with built-in clock and delayed start facility for overnight, weekend, and holiday periods
  • Independent, selectable flushes – either standard flush or extended flush
  • Automatic alerts when it is time for routine maintenance and service or to change reagents.

Thermo Shandon Cryostat

Additional Specifications

Dimensions (H x W x D): : 52' x 22' x 25' (132 x 56 x 33cm)
Power Requirements: : 1200VA
Weight: : 353 lbs. (160Kg)
Included with Product: : Wax Drain Container, Reagent Storage Bottles (12 included with unit), Reagent Bottle Labels, Charcoal Filter, Tissue Basket Handle, Viton Lid Seal, Cassette Basket, Reagent Bottle Pour Spout, Spatula, Wax Drain Key, Operator Manual (Specify Language), Quick-Reference Cards, Service Record Book
Agency Approvals: : Designed to meet IEC 61010, CSA, UL, and CE Mark (IVDD compliant).

Features:

The Shandon Cytospin 3 Centrifuge offers excellent preparations. As the centrifuge produces a monolayer of cells within a clearly defined area, the cytofunnels load in a tilted position to prevent cell loss. They also move to an upright position during operation to deposit cells. Additionally, the Cytospin 3 is equipped with a sealed head protects the user from the danger of aerosoling pathogenic samples. Within the safety of a microbiological cabinet, the cytoclips load and unload easily without contact with the sample. The Shandon Cytospin 3 centrifugeis a versatile and reliable cytocentrifuge which is ideal suited for applications inclusing hematology, oncology, cytology, rheumatology, virology, microbiology and immunochemistry. The Shandon Cytospin III was the first centrifuge to use low-speed centrifugal forces to separate and deposit monolayer of cells on slides, the Cytospin 3 centrifuge helps maintain cellular integrity. Simultaneously spinning up to 24 samples in 12 chambers, this Shandon centrifuge uses microtitre strips. A truly flexible instrument, the Cytospin 3 centrifuge has disposable sample chambers which are available in sizes to match the collection requirements of a wide range of samples. The Shandon Cytospin 3 centrifuge is useful in application areas such as hematology, oncology, cytology, histology, rheumatology, virology, serology, microbiology, and immunochemistry. Other features of the Cytospin 3 include: 9-program memory, programmable acceleration speeds (200-2,000 rpm) that ensure protection of all cell types, and disposable chamber compatibility of various sizes to accommodate a wide range of samples

Specifications:

  • Sample Volume: 0.5 mL
  • Cycle Duration: 1-99 min
  • Samples/run: 24, depending on cytofunnel
  • Revolutions: Max speed of 100 or 2000RPM
  • Power: 120 VAC 50/60 Hz
  • Dimensions: 21.6” x 38” x 55.9” (H x W x D)